Added ability to read registers in a sperate collection class
- multiple bugfixes
This commit is contained in:
@@ -1,44 +1,101 @@
|
||||
using System;
|
||||
using System.Threading.Tasks;
|
||||
using System.Linq;
|
||||
using System.Text.Json;
|
||||
using MewtocolNet;
|
||||
using MewtocolNet.Responses;
|
||||
using MewtocolNet.RegisterAttributes;
|
||||
using System.Collections;
|
||||
using MewtocolNet.Logging;
|
||||
|
||||
namespace Examples {
|
||||
class Program {
|
||||
static void Main(string[] args) {
|
||||
|
||||
Console.WriteLine("Starting test");
|
||||
|
||||
public class TestRegisters : RegisterCollectionBase {
|
||||
|
||||
//corresponds to a R100 boolean register in the PLC
|
||||
[Register(100, RegisterType.R)]
|
||||
public bool TestBool1 { get; private set; }
|
||||
|
||||
//corresponds to a R100 boolean register in the PLC
|
||||
[Register(RegisterType.X, SpecialAddress.D)]
|
||||
public bool TestBoolInputXD { get; private set; }
|
||||
|
||||
//corresponds to a DT1101 - DT1104 string register in the PLC with (STRING[4])
|
||||
[Register(1101, 4)]
|
||||
public string TestString1 { get; private set; }
|
||||
|
||||
//corresponds to a DT7000 16 bit int register in the PLC
|
||||
[Register(7000)]
|
||||
public short TestInt16 { get; private set; }
|
||||
|
||||
//corresponds to a DTD7001 - DTD7002 32 bit int register in the PLC
|
||||
[Register(7001)]
|
||||
public int TestInt32 { get; private set; }
|
||||
|
||||
//corresponds to a DTD7001 - DTD7002 32 bit float register in the PLC (REAL)
|
||||
[Register(7003)]
|
||||
public float TestFloat32 { get; private set; }
|
||||
|
||||
//corresponds to a DT7005 - DT7009 string register in the PLC with (STRING[5])
|
||||
[Register(7005, 5)]
|
||||
public string TestString2 { get; private set; }
|
||||
|
||||
//corresponds to a DT7010 as a 16bit word/int and parses the word as single bits
|
||||
[Register(7010)]
|
||||
public BitArray TestBitRegister { get; private set; }
|
||||
|
||||
//corresponds to a DT1204 as a 16bit word/int takes the bit at index 9 and writes it back as a boolean
|
||||
[Register(1204, 9, BitCount.B16)]
|
||||
public bool BitValue { get; private set; }
|
||||
|
||||
|
||||
}
|
||||
|
||||
class Program {
|
||||
|
||||
static void Main(string[] args) {
|
||||
|
||||
Task.Factory.StartNew(async () => {
|
||||
|
||||
//attaching the logger
|
||||
Logger.LogLevel = LogLevel.Critical;
|
||||
Logger.OnNewLogMessage((date, msg) => {
|
||||
Console.WriteLine($"{date.ToString("HH:mm:ss")} {msg}");
|
||||
});
|
||||
|
||||
//setting up a new PLC interface and register collection
|
||||
MewtocolInterface interf = new MewtocolInterface("10.237.191.3");
|
||||
TestRegisters registers = new TestRegisters();
|
||||
|
||||
interf.AddRegister<short>("Cooler Status",1204);
|
||||
interf.AddRegister<string>(1101, 4);
|
||||
|
||||
interf.WithPoller();
|
||||
|
||||
interf.RegisterChanged += (o) => {
|
||||
Console.WriteLine($"DT{o.MemoryAdress} {(o.Name != null ? $"({o.Name}) " : "")}changed to {o.GetValueString()}");
|
||||
};
|
||||
//attaching the register collection and an automatic poller
|
||||
interf.WithRegisterCollection(registers).WithPoller();
|
||||
|
||||
await interf.ConnectAsync(
|
||||
(plcinf) => {
|
||||
|
||||
Console.WriteLine("Connected to PLC:\n" + plcinf.ToString());
|
||||
//reading a value from the register collection
|
||||
Console.WriteLine($"BitValue is: {registers.BitValue}");
|
||||
|
||||
//read back a register value
|
||||
var statusNum = (NRegister<short>)interf.Registers[1204];
|
||||
Console.WriteLine($"Status num is: {statusNum.Value}");
|
||||
//writing a value to the registers
|
||||
Task.Factory.StartNew(async () => {
|
||||
|
||||
await Task.Delay(2000);
|
||||
//inverts the boolean register
|
||||
interf.SetRegister(nameof(registers.TestBool1), !registers.TestBool1);
|
||||
//adds 10 each time the plc connects to the PLCs INT regíster
|
||||
interf.SetRegister(nameof(registers.TestInt16), (short)(registers.TestInt16 + 10));
|
||||
//adds 1 each time the plc connects to the PLCs DINT regíster
|
||||
interf.SetRegister(nameof(registers.TestInt32), (registers.TestInt32 + 1));
|
||||
//adds 11.11 each time the plc connects to the PLCs REAL regíster
|
||||
interf.SetRegister(nameof(registers.TestFloat32), (float)(registers.TestFloat32 + 11.11));
|
||||
|
||||
interf.SetRegister(nameof(registers.TestString2), new Random().Next(0, 99999).ToString());
|
||||
|
||||
});
|
||||
|
||||
},
|
||||
() => {
|
||||
Console.WriteLine("Failed connection");
|
||||
}
|
||||
);
|
||||
|
||||
|
||||
});
|
||||
|
||||
Console.ReadLine();
|
||||
|
||||