Open Questions

  • What is the HW information byte for?
  • What are the last bytes of the EXRT message for?

Mewtocol Init

PLC TYPE CPU Code Machine Code HW Information
FPX C14 R 20 70 02
FPX C30 T 20 77 02
FPX-H C14 R 20 A0 01
FPX-H C30 T 20 A5 01

FPX 16k C14R Actual Response Examples

%EE$RT

Reponse Byte Description
20 Model code
25 Version
16 Prog capacity
80 Op mode
00 Link unit
E1 Error flag
2D00 Self diag error

%EE$EX00RT Normal Operation

Reponse Byte Description
00 Extended mode
32 Data item count
70 Machine type
00 Version (Fixed to 00)
16 Prog capacity in K
80 Operation mode / status
00 Link unit
E1 Error flag
2D00 Self diag error
50 Version
02 Hardware information
0 Number of programs
4100 Program size BCD
1600 Header size (no. of words) bcd
1604 System register size
96230000001480004 ?

%EE$EX00RT with error

Reponse Byte Description
00 Extended mode
32 Data item count
70 Machine type
00 Version (Fixed to 00)
16 Prog capacity in K
81 Operation mode / status
00 Link unit
60 Error flag
0000 Self diag error
50 Version
02 Hardware information
0 Number of programs
4100 Program size BCD
1600 Header size (no. of words) bcd
1604 System register size
96230000001480004 ?

What are the last bytes?

FP-X 16k C14R 96 23 00 00 00 14 80 00 4

FP-X 32k C30T/P 96 23 00 00 00 14 80 00 4

FP-XH 32k C30T/P 96 23 00 00 00 40 00 00 4

FP-XH 16k C14R 96 23 00 00 00 40 00 00 4

FP-XH 16k C14R Actual Response Examples

%EE$RT

Reponse Byte Description
20 Model code
16 Version
16 Prog capacity
81 Op mode
00 Link unit
60 Error flag
0000 Self diag error

Mewtocol-7 Com

Getting the status of the plc

%EE#RT

Normal plc would return the default, see above.

The FP7 series returns:

%EE$RT0000000100000000

This indicates that the device uses the Mewtocol 7 format

When trying to use EXRT the FP7 returns not supported

[R] %EE#EX00RT00

[S] %EE!42

Then request the status from the PLC using Mewtocol 7

[R] >@EEE00#30STRD00

[O] >@EEE00$30STRD

Reponse Byte Description
00 Read status (always 0)
07 series code: 7 = FP7
10 model code: 3 = CPS41E, 4 = CPS31E, 5 = CPS31, 6 = CPS41ES, 7 = CPS31ES, 8 = CPS31S, 9 = CPS21, 10 = ElC500
0000 user special order code (Not important)
0453 latest cpu version = 4.53
0453 communication cpu version = 4.53
0453 operation cpu version = 4.53
01 op mode = 4.53
00 error flag
0000 self diag error
00 sd card information