- add new checksum calculation for Mewtocol 7
MewtocolNet
An easy to use Mewtocol protocol library to interface with Panasonic PLCs over TCP/Serial.
Disclaimer
This library is not an official panasonic product nor does panasonic provide financial support or limitations in any form. This software was written by WOLF Medizintechnik GmbH (@WOmed/dev).
Features
Features that are not checked still need implementation
- Read out stats from your PLC
- Read and write registers in real time
- Dynamic register type casting from properties
- Change run / prog modes
- Write / read byte blocks in a whole chain
- Upload / Download programs to the PLC
- Reading / writing PLC system registers
Support
.NET Support
This library was written in netstandard2.0 and should be compatible with a lot of .NET environments.
For a full list of supported .NET clrs see this page
PLC Support
This library was only tested with a few PLCs, other types that support the Panasonic Mewtocol protocol might work. Use at your own risk, others might follow with community feedback
For a Support List check this table
Where is the RS232/Serial support?
Support for the serial protocol will be added soon, feel free to contribute
Installing
Use the dotnet CLI and run
dotnet add package Mewtocol.NET
Protocol description
Panasonic has published a protocol definition on their site. Refer to this site if you want to see the general functionality or add / report missing features.
This library is at the time not feature complete, but all essential features are provided
Usage
See More examples here
Connecting to a PLC
Connecting to a PLC is as simple as
//attaching a logger
Logger.LogLevel = LogLevel.Verbose;
Logger.OnNewLogMessage((date, msg) => {
Console.WriteLine($"{date.ToString("HH:mm:ss")} {msg}");
});
//setting up a new PLC interface
MewtocolInterface plc = new MewtocolInterface("192.168.115.5");
await plc.ConnectAsync();
Reading data registers / contacts
- Create a new class that inherits from
RegisterCollectionBase
public class TestRegisters : RegisterCollectionBase {
//corresponds to a R100 boolean register in the PLC
[Register(100, RegisterType.R)]
public bool TestBool1 { get; private set; }
//corresponds to a XD input of the PLC
[Register(RegisterType.X, SpecialAddress.D)]
public bool TestBoolInputXD { get; private set; }
//corresponds to a DT7012 - DT7013 as a 32bit time value that gets parsed as a timespan (TIME)
//the smallest value to communicate to the PLC is 10ms
[Register(7012)]
public TimeSpan TestTime { get; private set; }
//corresponds to a DT1101 - DT1104 string register in the PLC with (STRING[4])
[Register(1101, 4)]
public string TestString1 { get; private set; }
}
- Connect to the PLC and attach the register collection and logger
- attach an automatic poller by chaining
.WithPoller()after the register attachment
//setting up a new PLC interface and register collection
MewtocolInterface plc = new MewtocolInterface("192.168.115.5");
TestRegisters registers = new TestRegisters();
//attaching the register collection and an automatic poller
plc.WithRegisterCollection(registers).WithPoller();
await plc.ConnectAsync(
(plcinf) => {
//reading a value from the register collection
Console.WriteLine($"Time Value is: {registers.TestTime}");
}
);
- Your properties are getting automatically updated after the initial connection
Note! this is not your only option to read registers, see here
Writing data registers / contacts
Registers are stored in an underlying layer for automatic handling, each register has a unique name and address.
Classes that derive from RegisterCollectionBase reference these registers automatically using attributes.
All the heavy lifting is done automatically for you, setting this up is described here
Asynchronous
This operations awaits a task to make sure the register was actually set to your desired value before progressing
//sets the register to false
await plc.SetRegisterAsync(nameof(registers.TestBool1), false);
//set the current second to the PLCs TIME register
await plc.SetRegisterAsync(nameof(registers.TestTime), TimeSpan.FromSeconds(DateTime.Now.Second));
Synchronous
Sets the register without feedback if it was set
You can use the method to set a register
//inverts the boolean register
plc.SetRegister(nameof(registers.TestBool1), !registers.TestBool1);
//set the current second to the PLCs TIME register
plc.SetRegister(nameof(registers.TestTime), TimeSpan.FromSeconds(DateTime.Now.Second));
//writes 'Test' to the PLCs string register
plc.SetRegister(nameof(registers.TestString1), "Test");
or write to a register in your RegisterCollectionBase directly (you need to attach a register collection to your interface beforehand)
//inverts the boolean register
registers.TestBool1 = true;
You can also set a register by calling its name directly (Must be either in an attached register collection or added to the list manually)
Adding registers to a manual list
plc.AddRegister<bool>(105, _name: "ManualBoolRegister");
Reading the value of the manually added register
//get the value as a string
string value = plc.GetRegister("ManualBoolRegister").GetValueString();
//get the value by casting
bool value2 = plc.GetRegister<BRegister>("ManualBoolRegister").Value;
//for double casted ones like numbers
var value2 = plc.GetRegister<NRegister<short>>("NumberRegister").Value;